Display
1.15 inch touch screen with no dead space.
2.New interface design with user friendly layout and colour assortment.
3.Day/Night display mode brings a better visual perception to users. Night mode suitable for dark environment.
4.Display a full range of ventilation modes including VCV, PCV, PSV, SIMV-V, SIMV-P, PA-VC. Also displays pressure, flow rate, volume and CO2 waveform in same interface.
5.Comprehensive monitoring capabilities include ventilation parameters monitoring, preset parameters, alarm indication and breathing waveform monitoring.
6.Electronic flowmeter with electronic gas mixing.
7.Backup rotameter is also applied for safety issue.
8.Typical display for Zoom in/out, comparison, freeze.
9.Show last 72 hrs trends for different monitoring parameters.
10.3000 logs record for setting and alarm.
Monitoring
1.Comprehensive monitoring capabilities include VT, minute volume range, airway pressure, I:E range, lung compliance, plateau, O2 concentration, CO2(optional).
2.Customized monitoring windows.
Integrated Breathing Circuit
1.Integrated breathing circuit with APL valve, excellent tightness and easy to use.
2.Low essential resistance, good mechanical compliance.
3.Replacing drive bellow is not required when operating pediatric anesthesia.
4.Drain cup design ensure no water trap in the breathing circuit.
5.Built-up design duo flow sensor(no maintenance required).
6.2L Large volume of CO2 canister.
7.Autoclave 134 ℃。
High-precision Vaporizer
1.Vaporizer can support low flow anesthesia(as low as 0.2L/min) and large flow anesthesia (up to 15L/min).
2.Accurate output of concentrations under varying conditions of pressure, flow and temperature.
3.Support Selectatec mounting type and cagemount compatible.
4.Fill-in type: pouring.
5.Agent type: Isoflurane, Enflurane, Halothane, Sevoflurane.
6.Service Free.
ACGO
1.International standard design.(diameter:22mm)
2.Convenient for patients’ oxygen inhalation and postoperative recovery.
3.To connect with T circuit or bain circuit for open-operation.
AGSS (Optional)
1.Made by aluminum alloy. High strength, light weight, never rusts.
2.Enhance the safety of the environment in which members of staff in close proximity with waste anaesthetic gases and vapors ( agents) work.
Module plug in design (Optional)
Plug in design available for monitoring SPO2, CO2, FiO2 and 5 AA(anesthetic gases module).
Yoke system
Up to 3 back up cylinders with A-type 11L size.
Technique Specifications | |
Physical Specifications | |
Dimensions | 70*85*140cm |
Weight | 65kg |
Casters | Front wheels with lock |
Screen | 15 inch LCD touchabl |
Working Specifications | |
Power | AC 220V+/-10%,50Hz+/-2% |
Pipeline Supply | |
Gas configuration | O2,N2O,Air |
Pipeline input range | 280-600Kpa |
Battery Power | |
Run-time | ≥180 mins |
Pre-setting Functions | |
Language | English, Chinese, etc. |
Calibration | Automatic |
Applications | |
Patient range | Adult/Pediatric |
Ventilator Specifications | |
Modes of Ventilation | |
VCV | Volume Controlled Ventilation |
SIMV-V | Synchronized Intermittent Mandatory Ventilation-Volume |
SIMV-P | Synchronized Intermittent Mandatory Ventilation-Pressure |
MANUAL | Manua |
A/C | Assist/Control Ventilation |
PCV | Pressure Control Ventilation |
PSV | Pressure Control Ventilation |
PA-VC | Pressure-regulated Volume Control |
STAND-BY | STAND-BY |
Ventilator Parameter | |
Working type | Electronic control, pneumatic driven |
Tidal Volume range | 10-1500ml |
Pressure range | 5-60cmH2O |
Rispriation rate range | 1-100bpm(1-40bpm under SIMV) |
I:E range | 4:1-1:8 |
Ptrigger range | -20-20cmH2O(based on PEEP) |
Flow trigger | 0-15L |
Minute volume range | >18L/Min |
SIGH range | 0-5/100 |
System Standard | |
Hypoxic guard system | N2O cut-off Valve, O2 concentration>25% |
Safety valve | <12.5Kpa |
Fresh gas compensation | 25-75L/mi |
Volume of CO2 absorber | 2L |
Flow meter | E-flowmeter; 0.1-15L/min O2; 0.1-15L/min NO2, 0.1-15L/min air |
Vaporizer | 2 Selectetac, maximum 2 mounts (Isoflurane/Enflurane/Sevoflurane/Halothane) |
Monitoring | |
Display graphics | Waveforms of P-T, F-T,V-T, loops of P-V, V-F, F-P(Zoom in/out, comparison, freeze) |
Types | VT, minute volume range, airway pressure, I:E range, lung compliance, plateau, O2 concentration, CO2(optional), Anaesthetic Gas(optional) |
Alarm Limits | |
Audio/Visual | No tidal volume, MV, Paw, FiO2 limitation O2,Air failure, AC power failure, Battery low. |
PEEP | |
Type | Integrated, Electronic control |
Range | OFF, 3-30cmH2O |
Auxiliary features | |
ACGO | Auxiliary Common Gas Outlet |
Yoke system(Pin-index) | Support 11L cylinder, O2/N2O |
AGSS | Anesthetic Gas Scavenging Systems(optional |
Communication Interface | Ethernet, USB, VGA |
Worktable | Optional |
Patient Monitor | Optional |
E-anesthesia record | Optional |
Auxiliary Oxygen meter | Optional |