The T80 is an advanced turbine ventilator for provide acute respiratory support for adult, pediatric and neonatal use. Excellent ventilation performance and comprehensive monitoring capabilities adapt to various clinical requirements.
NEW generation of ventilator
○ Molding production, tight structure.
○ Turbine driven machine.
○ 12.1 inch touch screen.
○ New interface design with user friendly layout and color assortment.
○ Intelligence operating system.
○ Can display 3 types of waveform in same interface.
○ 3 level of audio and visual alarm indication, adjustable sound volume.
Ventilation performance
○ Integrated turbine design can continuous delivery high low more than 220L/min with rapid response of compensation.
○ Comprehensive ventilation modes for volume and pressure based, with selection of pressure support, spontaneous breath and non-invasive ventilation. Ventilator is applicable for wide range of patients and clinical situations.
○ Quick response for patient’s trigger which improved the synchrony between patient- ventilator.
○ Graphic capabilities for trends and event record, long time monitoring for all types of ventilation parameters.
○ Provide respiratory support from neonatal to adult.
Technique Specifications | |
Physical Specifications | |
Dimensions(L*W*H) | 40*42*36cm |
Weight | Approximately 13kg ( Main unit) Approximately 26kg ( with Trolley) |
Casters | Front wheels with lock |
Display | |
Display size | 12.1 inch TFT touch screen |
Display Resolution | 1280*800pixels |
Brightness | Adjustable |
Pipeline Supply | |
Gas configuration | Medical-grade Oxygen |
Pipeline input range | 280-600KPa |
Power&Battery | |
External AC Power Supply Input Voltage | 100-240V |
Input Frequency | 50/60Hz |
Input | 2.5A Max |
Battery type | Build-in Lithium-ion Battery, 12V |
Ventilator Specifications | |
Patient Type | Adult, Pediatric, Neonatal |
Modes of Ventilation | |
VCV | Volume control ventilation |
AC-V | Assist Control-Volume Ventilation |
SIMV-V | Synchronized Intermittent Mandatory Ventilation-Volume |
PA-VC | Pressure Auto-Volume Control |
PCV | Pressure Control Ventilation |
AC-P | Assist Control-Pressure Ventilation |
SIMV-P | Pressure Synchronized Intermittent Mandatory Ventilation |
PSV | Pressure Support Ventilation |
CPAP | Continuous Positive Airway Pressure |
BIPAP | Bilevel Positive Airway Pressure |
APNEA | APNEA |
APRV | Airway Pressure Release Ventilation |
Assistant therapy | |
Nebulization | |
O2 Remedy | |
Real Time Graphics | |
Waveforms | Pressure-time Waveform Flow-time Waveform Volume-time Waveform (Waveforms with freeze function) |
Loops | Pressure-volume Loop Flow-time Loop Pressure-flow Loop ( Loops with freeze, Zoom in&out, comparison function) |
Waveforms and loops display | Could simultaneous display 3 waveforms and 3 loops. |
Controlled Parameters | |
Tidal Volume range | 2-2000ml |
Minute Volume | 250-1500ml/min |
Min Tinsp/Texp | 150-1000ms |
Respiratory rate | 4-200bpm |
PEEP | 0-40cmH2O |
Max Inspiration pressure | 21%-100% |
Ptrigger Range | 90cmH2O |
Fio2 | 21-100% |
Flow-trigger: | 0.5-30L/min |
Pressure-trigger | -20-20cmH2O |
Sigh | On/Off, 1/5 times every 100 breath cycle |
Monitoring Parameters | |
VTe mand, VTe spon, VTi mand, VTi spon Mvemand, Mve spon, Mvimand, Mvi spon, MVe total, RR mand, RR spon., Tinsp Texp, Ppeak, Pplat, PEEP, Pmean, FiO2, Vleak, Flowpeak_insp, Flowpeak_exp, Pmin, RSBI, P0.1, C, R, RCinsp, RCexp, WOB | |
O2 Remdy | |
Oxygen concentration | 21%-100% |
Flow | 4-60L/min |
Trend & Event Log | |
Trend Length | 72 hrs for monitoring parameters |
Event Log | 3000 logs |
Communication Interface | |
HDMI, Ethernet, USB, CO2 Module Connector(Optional | |
Environmental Operating Conditions | |
Temperature (around module) | -20-+60 degrees C |
Operating temperature (outside) gas inlet | -20-+50 degrees C |
Relative air humidity | 5-95% R.H. |
Ambient Air Pressure | 500-1100 mbar |
Noise generation | <45 dB |