Features
○ Removable 15 inch large touch screen, hang-up type that allows the operator to hang the screen pad wherever requires.
○ Easy to operate.
○ Thinner screen pad with easy handle.
○ Day and night mode change.
○ Support adult and pediatric ventilation.
○ Professional separate non-invasive module, support leakage compensation.
○ Automatic alarm setting adjusting.
○ Assistant Nebulization treatment/O2 therapy.
○ Multi-mode ventilation function(IPPV, SIMV, PSV,PCV, CPAP,A/C, BIPAP,APRV,SIPPV,SIGH).
○ Intelligence operating system.
○ Air compressor support(optional).
○ Self testing and calibration with faulty code display.
Technique Specifications Physical Specifications Dimensions 45*55*140cm Weight 65kg Casters Central brake with lock Screen Removable,hang-up type Display Colour LCD, 15 inch with day/night mode Display graphics Waveforms of P-T, F-T, V-T Loops P-V, F-V, F-P Screen control Touch screen Air Compressor Specifications Power AC 220V+/-10%, 50Hz±2% Output pressure 0.4±0.1MPa Noise ≤50dB Ventilator Specifications Modes of Ventilation VCV Volume control ventilation APNEA(A/C) Assist Control V-SIMV Volume-SIMV P-SIMV Pressure-SIMV V-SIMV/PSV Volume-SIMV/Pressure Support Ventilation MANUAL Manual CPAP Continuous Positive Airway Pressure PA-VC Pressure Auto-Volume control PCV Pressure Control Ventilation PSV Pressure Support Ventilation ARPV Airway Pressure Release Ventilation BIPAP Bi-level Positive Airway Pressure SIGH SIGH O2 Remedy Oxygen Remedy Ventilator parameter Tidal Volume range 10-2000ml Tidal Volume range 5-80 cmH2O Respiration Rate Range 1-150 bpm (1-40 bpm under SlMV) Insp Time 0.2-12s Oxygen concentration 21%-100% Ptrigger Range -20-0cmH2O Apnea Ti Range 0-6s PEEP Type Integrated, Electronic control Range 0-40cmH2O Monitor Vti, Vte, l:E, Freq, PEEP, Pplat, Ppeak, Pmean, MV, Resistance, Exp R, Compliance, Dynamic C, FiO2, Ptri depth,Ftri depth, RSBl (Optional-FiCO2, EtCO2, C2O/C) Alarm Limits Visual/Audio No tidal volume, MV, Paw, FiO2 limitationO2,Air failure, AC power failure, backup low Pipeline supply Gas configuration O2, Air Pipeline input range 280-600kPa Battery Power Battery Type Lead-acid 12V4Ah Run-time Typical 120 mins Pre-setting functions Language English, Chinese Calibration Touch pad/Flow rate/pressue/FiO2 General settings Password/time/day&night mode
Brightness setting
Record historyApplications Patient therapy type Audit/Pediatric Invasive
Audit/Pediatric Non-InvasiveAssistant therapy Nebulization treatment Oz Remedy Auxiliary suction function(Optional) Interface specifications Communication port RS-232, HDMl, Ethernet, USB Environmental Conditions Operating Temp 5℃~40℃ Storage Temp -10℃~+40℃ Humidity ≤80% Atmosphere pressure 960 hPa~1040 hPa